    Hi

    just a quick question i have a system running at the moment which consists of 2 x 250 watt trina panels, 30a mppt tracer controller, 1500watt 24v inverter and 2 x 12v 220ah 1000a batteries.

    i would like to add another two batteries for more storage, the batteries i would like to add are 12v 180ah 1050a will this work or do the batteries have to be the same?

    thanks

    alan

  • #2
    Batteries need to all be matched - preferably from the same lot. Mixing brands or sizes is asking for long term trouble.

    This site http://www.smartgauge.co.uk/batt_con.html has a article that talks about the problems that arise when even the battery cables are mis-matched.
    Powerfab top of pole PV mount (2) | Listeroid 6/1 w/st5 gen head | XW6048 inverter/chgr | Iota 48V/15A charger | Morningstar 60A MPPT | 48V, 800A NiFe Battery (in series)| 15, Evergreen 205w "12V" PV array on pole | Midnight ePanel | Grundfos 10 SO5-9 with 3 wire Franklin Electric motor (1/2hp 240V 1ph ) on a timer for 3 hr noontime run - Runs off PV ||