I am in the process of having a trailer built for us and would like the help of some experts to put together a package that is safe and reliable.
I like the idea of using solar to keep the batteries topped off and to keep the generator from running as much. I don't need the panels to support big loads just small consistent loads like the DC fridge. I have a Onan SD10000 diesel generator to charge batteries when needed. I would like to run a microwave and small tools without having to start the generator every time.
Consistent known loads
Vitrifrigo fridge 4.4 A, 56.89 watts running
Temporary loads are all over the place with interior and exterior led Lights.
work lights 150w
living lights 30w
Espar Airtronic furnace model D5 80W running on high
With my very limited knowledge in this field, I have came up with this.
Magnum Energy inverter charger MS-2012 or MS-2812
system control ME-ARC
auto gen start ME-AGS-N
Sharp panels 250w NDQ250F7 Qty 2
Blue Sky charge controller SB-3024il
I can get wholesale on Deka batteries so i would like to find a good fit from them. I know two 8D batteries would be small on a system that relied on solar only, would it be sufficient for me? What will it take to run overnight with furnace running nonstop and refrigerator cold and have batteries still in the safe zone?
Thanks for the help
Jordan
I like the idea of using solar to keep the batteries topped off and to keep the generator from running as much. I don't need the panels to support big loads just small consistent loads like the DC fridge. I have a Onan SD10000 diesel generator to charge batteries when needed. I would like to run a microwave and small tools without having to start the generator every time.
Consistent known loads
Vitrifrigo fridge 4.4 A, 56.89 watts running
Temporary loads are all over the place with interior and exterior led Lights.
work lights 150w
living lights 30w
Espar Airtronic furnace model D5 80W running on high
With my very limited knowledge in this field, I have came up with this.
Magnum Energy inverter charger MS-2012 or MS-2812
system control ME-ARC
auto gen start ME-AGS-N
Sharp panels 250w NDQ250F7 Qty 2
Blue Sky charge controller SB-3024il
I can get wholesale on Deka batteries so i would like to find a good fit from them. I know two 8D batteries would be small on a system that relied on solar only, would it be sufficient for me? What will it take to run overnight with furnace running nonstop and refrigerator cold and have batteries still in the safe zone?
Thanks for the help
Jordan